Gas Volume Analyzer GVA-700

Category:Laboratory > Analytical Instrument
Product Name:Gas Volume Analyzer GVA-700
Price(USD):0.00
Company:KYOTO ELECTRONICS MANUFACTURING (Shanghai) Co., LTD.

Basic Info
  • Factory Location: Kyoto, japan

    Main Sales Markets: Western Europe,Asia,Middle East

  • Sample Provided: yes

    This measuring instrument automatically measures gas volume / internal gas pressure, air content and oxygen concentration for quality control in the bottling process of carbonated drinks, etc.

    Applications

    [Soft drinks and brewery]

    • Can automatically measure gas volume / internal gas pressure, air content and oxygen concentration for quality control in the bottling process of soft drinks, etc.
    Measurement items Application

    Gas volume / internal gas pressure

    (volume of carbon dioxide)

    Carbonated drink

    (PET bottles, metal cans and glass bottles)

    Air content

    *measurement capability of oxygen concentration (option)

    Carbonated drink

    (PET bottles, metal cans and glass bottles)

    Inside gas pressure

    Carbonated / non-carbonated drink

    (PET bottles, metal cans and glass bottles)

    This measurement instrument cannot be applied to the following containers.

    ・ A sample container using a cork
    ・ A sample container of a special shape

    • Supported standard

    Control items
    Measuring items

    Gas volume
    (internal gas
    pressure)

    Air content

    Gas volume
    + air content
    (simultaneous
    measurement)

    Oxygen
    concentration

    Option *1

    Inside
    gas
    pressure
    Soft drinks Carbonated drink A A A S A
    Carbonated fruit juice S S S S S
    Fruit juice - - - - S
    Coffee - - - - A
    Brewery Beer A A A S A
    Cocktail with tonic water A A A S A
    Cocktail with fruit juice S S S S S
    Local beer A A A S A

    A:All can be measured S:Some samples can be measured -:Not available
    *1 Oxygen concentration can be measured if its volume is over 8mL.

    Features

    • Only by setting a sample container on the sample stage, all the procedures are performed automatically; punching, depressurizing, stirring of a sample, absorption of measurement gas and so on.
    • By continuously rotating a sample container, the balance pressure of gas and sample temperature in the container are measured and calculated into gas volume / internal gas pressure, which are displayed on the LCD.
    • Furthermore, carbon dioxide in the sample gas is absorbed into alkaline solution to leave only nitrogen and oxygen, and then calculate air content using the residual gas volume and oxygen concentration, which are displayed on the LCD.
    • Data printing is available by connecting an external printer to the RS-232C port and 100 measurement results can be recorded in a USB flash drive via the USB port.

    The features of GVA-700 are as follows.

    1. No personal error/Fully automated measurement.
    2. Less work/Less possibility to contact alkaline solutions.
    3. Improved maintainability
      With the detachable front cover, easy to maintain the sniffing valve and the filter.
    4. Compact size, space saving
      Size: 495(W) x555(D) x570(H) mm
      (Conventional model : 670(W) x505(D) x680(H) mm)
      Easy to secure the installation space with the slide cover.
    5. Inside the absorption cylinder is visible.
      Inside of the absorption cylinder can be checked visually.
    6. Improved software
      Store 20 methods and 100 measurement results.
    7. USB flash drive
      Load methods and store measurement results with a USB flash drive.

    Specification

    Measuring
    items
    1)Gas volume / internal gas pressure of carbonated drink
    2)Gas volume / internal gas pressure of carbonated drink,air content and oxygen concentration
    3)Inside gas pressure of non-carbonated drink
    Measuring
    range
    Pressure 55 to 10cmHg and 9.8kPa to 0.490MPa
    (0.1 to 5.0kgf/cm2G)
    Temperature 0 to 50℃
    Residual gas
    volume
    0 to 30mL(Residual gas volume after the absorption of alkaline aqueous solution)
    Oxygen 
    concentration
    0 to 21%(Oxygen concentration measurement is not available when the residual gas volume is 8mL or less.)
    Measurement
    accuracy
    Pressure +/- 0.001MPa(+/- 0.01kgf/cm2G)
    Temperature +/- 0.05℃
    Residual
    gas volume
    +/- 2% (for 5mL or over and 30mL or less)
    for the measured value
    +/- 0.1mL (for 0mL or over and 5mL or less) for the measured value
    Oxygen
    concentration
    +/- 0.2%
    Calibration
    Gas volume
    measuring unit

    Pressure sensor-zero : pressure gauge for calibration 0.000MPa(0.00kgf/cm2G)
    Pressure sensor-span : pressure gauge for calibration 0.490MPa (5.00Kgf/cm2G)
    Temperature sensor : standard thermometer, pure water

    Air content
    measuring unit
    Pressure sensor-zero : pressure gauge for calibration 0.000MPa(0.00kgf/cm2G)
    Pressure sensor-span : pressure gauge for calibration 0.098MPa (1.00Kgf/cm2G)
    Oxygen
    measuring unit
    Oxygen sensor : automatic calibration during pretreatment (manual calibration is possible)
    Temperature sensor : room temperature
    Measurement
    time

    For measuring gas volume / internal gas pressure only : approximately 90 seconds for one sample
    For measuring gas volume, air content and oxygen concentration : 6 to 16 minutes for one sample
    Note: Measuring time varies according to sample and condition

    Sample container PET bottles : 2.0L or smaller (190mL cans, various PET containers)
    Maximum container : 110 (φ) x 320 (H) mm
    Display 16-digit and 1-row LCD (with backlight)
    Number of main unit stored data Measurement conditions are storable to the main unit up to 20 sets
    Measurement data as many as the latest 100 samples are storable
    By using a USB flash drive, can be taken out in a CSV format
    Calculation
    Gas
    volume
    Calculation of gas volume / internal gas pressure by using the balance pressure inside the sample container and sample temperature.
    Calculation formula for the soft drink standard(*1) or the EBC standard (*2) can be selected.

     

     

    *1 According to “Chart 13-2 Table of absorption coefficients of carbon dioxide” in revised Soft drinks overseen by Japan Soft Drink Association
    *2 According to ASBC Methods of Analysis -Beer-13: Dissolved Carbon Dioxide

    Air
    Content
    Calculation of air content by using the residual gas volume and oxygen concentration after absorbing carbon dioxide in the alkaline aqueous solution

    External
    output

    RS-232C 1ch For an external printer or an external computer
    1) Compatible printer
    IDP-100、DP-600
    2) Printout data
    Date and time, Measurement mode, Sample No., 
    Gas volume (V/V, g/Kg), Internal gas pressure (MPa, Kgf/cm2G), Pressure (MPa, Kgf/cm2G,cmHg), Temperature(℃), Air content (mL), Oxygen concentration (%), Residual gas volume (mL)
    USB 1ch For method entry, data storage
    Ambient condition
    Temperature 5 to 35℃
    Humidity 85%RH or below
    Power supply
    Voltage AC100V to 240V +/- 10V
    Frequency 50/60Hz +/- 1Hz
    Power 
    consumption
    20W
    Coating Alkali-resistance
    Dimensions 495(W)×555(D)×570(H) mm
    Weight Approximately 38kg
    Supplied air 
    pressure
    Instrument air : pressure of 0.490 to 0.686MPa (5 to 7kgf/cm2G)
Send your message to this supplier
  • From:
  • To:
    KYOTO ELECTRONICS MANUFACTURING (Shanghai) Co., LTD.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service