PCR Workstations

Category:Cleanroom System > Air Purification
Product Name:PCR Workstations
Price(USD):0.00
Company:JeioTech-Shanghai REF. Partner

Basic Info
  • Factory Location: korea

    Main Sales Markets: North America,Western Europe,Eastern Europe,Australasia,Asia

  • Sample Provided: no

    PCR Workstations

    Specially designed to minimize the sample contamination during PCR

    Model Name : PW-01/11/21

       캡처.JPG

    Performance
    • ISO class 4 (US class 10) HEPA filter for optimal protection against cross-contamination.
      (average life span of HEPA filter: 3 years – it depends on the test room conditions)
    • High-quality polyester fiber pre-filter (with minimal pressure loss and 85% arrestant on the A.F.I. test) for trapping larger particles and increasing the life of the main HEPA filter.
    • Effective sterilization using a long-life 254 nm UV lamp. (average life span of UV lamp: 8,000 hours)
    • Built in anti-glare fluorescent lamp minimizes shadows and relieves eye strain.
    Convenience
    • User-friendly microprocessor-based control panel.
    • Large capacity blower and easy blower speed adjustment by the control panel.
    • Easy-settable digital timer for UV light exposure to deactivate DNA and RNA contaminants. (wait off, max. 30min.)
    • Comfortable front access to cartridge type of filters for easy replacement.
    Safety
    • Interlocking safety door system shuts off UV light automatically when opening the door.
    • UV-blocking door and side panels made of transparent acrylic resin provides clear inside view.
    • UV over-exposure alarm and over-current protection.
    Model PW-01 PW-11 PW-21

    Air flow type

    Vertical

    Max. air volume (cmh / cfm)

    557 / 327

    697 / 408

    929 / 546

    Min. air volume (cmh / cfm)

    167 / 97

    209 / 121

    279 / 162

    Laminar airflow velocity (m / s / fpm)

    0.3 / 60

    Filter

    Air cleanliness

    ISO 14644-1 class 4

    HEPA filter

    Typical efficiency of 99.99% at 0.3 ㎛ US MIL-STD -282
    ; Micro glass fiber media, Particle board, Aluminum separator, Neoprene gaskets

    Pre filter

    Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber media

    Noise level (dBA)

    Typically < 60 dBA at blower speed

    Material

    Work surface

    10mm thick acrylic resin (clear type)

     

    Window (front, side / back)

    8mm / 10mm thick acrylic resin (clear type)

    Illumination

    Intensity

    Fluorescent lamp (lux)

    >1000

    UV density (㎼ / ㎠)

    165

    185

    330

    Capacity

    Fluorescent lamp (w)

    15 × 1ea

    20 × 1ea

    30 × 1ea

    UV lamp (w)

    15 × 1ea

    20 × 1ea

    30 × 1ea

    Dimension(W×D×H)

    Interior (mm / inch)

    700×585×602 / 27.5×23×23.7

    880×585×602 / 34.6×23×23.7

    1180×585×602 / 46.5×23×23.7

    Exterior (mm / inch)

    720×605×964 / 28×24×38

    900×605×964 / 35.4×24×38

    1200×605×964 / 47.2×24×38

    Net weight (Body) (kg / lbs)

    56.2 / 123.9

    64.2 / 141.5

    77.8 / 171.5

    Electrical  requirements (230V)

    60Hz, 1.3A 50Hz, 1.3A 60Hz, 1.4A 50Hz, 1.4A 60Hz, 1.5A 50Hz, 1.5A
    Cat. No. AAHB3001K AAHB3002K AAHB3011K AAHB3012K AAHB3021K AAHB3022K

    Electrical  requirements (120V)

    60Hz, 2.2A 60Hz, 2.7A 60Hz, 2.9A
    Cat. No. AAHB3003U AAHB3013U AAHB3023U

     

    General UV dose and time required

    Pathogen Average UV dose
    required
    (㎼ . s/㎠)
    Average UV time required (㎼/ ㎠ /sec.)
    PW-01 UVC-01 PW-11 UVC-11 PW-21 UVC-21
    165 300±10% 185 350±10% 330 300±20%
    S. enteritidis 4,000 25 15 22 10 13 9
    B. megatherium sp. (spores) 2,730 17 11 15 7 9 6
    B. subtilis 7,100 43 27 39 18 22 16
    Eberthella typhosa 2,140 13 8 12 6 7 5
    Escherichia coli (E. coli) 3,000 19 12 17 8 10 7
    Micrococcus candidus 6,050 37 23 33 16 19 13
    Proteus vulgaris 2,640 16 10 15 7 8 6
    Pseudomonas aeruginosa 5,500 34 21 30 14 17 12
    Pseudomonas aeruginosa 3,500 22 13 19 9 11 8
    S. typhimurium 8,000 49 30 44 21 25 18
    Shigella paradysenteriae 1,680 101 7 10 4 6 4
    Spirillum rubrum 4,400 27 17 24 11 14 10
    Staphylococcus albus 1,840 12 7 10   6 4

    ※ Permissible environmental conditions: temperature (20 to 25℃) and relative humidity (up to 60%).
    ※ Above listed applications are for general purpose use.

    • HEPA filter (for PW)

    • Fluorescent lamp

    • UV lamp

    for PCR workstations

    Cat. No. Description PW-01 PW-11 PW-21
    AAAB3511 Pre filter - -
    AAAB3512  
    AAAB3513  
    EDA9219 HEPA filter    -
    EDA9220 - -
    EDA9221 - -
    CHE4436 Fluorescent lamp - -
    CHE4410 - -
    CHE4409 - -
    CHE4431 UV lamp - -
    CHE4427 - -
    CHE4423 - -

     

Send your message to this supplier
  • From:
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service