In This Store
Category:Cleanroom System > Air Purification
Product Name:PCR Workstations
Price(USD):0.00
Company:JeioTech-Shanghai REF. Partner
Factory Location: korea
Main Sales Markets: North America,Western Europe,Eastern Europe,Australasia,Asia
Sample Provided: no
PCR Workstations
Specially designed to minimize the sample contamination during PCR
Model Name : PW-01/11/21
Model | PW-01 | PW-11 | PW-21 | |||||
---|---|---|---|---|---|---|---|---|
Air flow type |
Vertical |
|||||||
Max. air volume (cmh / cfm) |
557 / 327 |
697 / 408 |
929 / 546 |
|||||
Min. air volume (cmh / cfm) |
167 / 97 |
209 / 121 |
279 / 162 |
|||||
Laminar airflow velocity (m / s / fpm) |
0.3 / 60 |
|||||||
Filter |
Air cleanliness |
ISO 14644-1 class 4 |
||||||
HEPA filter |
Typical efficiency of 99.99% at 0.3 ㎛ US MIL-STD -282 |
|||||||
Pre filter |
Polyester fibers with an efficiency of 85% (A·F·I TEST); AL frame, Polyester fiber media |
|||||||
Noise level (dBA) |
Typically < 60 dBA at blower speed |
|||||||
Material |
Work surface |
10mm thick acrylic resin (clear type) |
||||||
|
Window (front, side / back) |
8mm / 10mm thick acrylic resin (clear type) |
||||||
Illumination |
Intensity |
Fluorescent lamp (lux) |
>1000 |
|||||
UV density (㎼ / ㎠) |
165 |
185 |
330 |
|||||
Capacity |
Fluorescent lamp (w) |
15 × 1ea |
20 × 1ea |
30 × 1ea |
||||
UV lamp (w) |
15 × 1ea |
20 × 1ea |
30 × 1ea |
|||||
Dimension(W×D×H) |
Interior (mm / inch) |
700×585×602 / 27.5×23×23.7 |
880×585×602 / 34.6×23×23.7 |
1180×585×602 / 46.5×23×23.7 |
||||
Exterior (mm / inch) |
720×605×964 / 28×24×38 |
900×605×964 / 35.4×24×38 |
1200×605×964 / 47.2×24×38 |
|||||
Net weight (Body) (kg / lbs) |
56.2 / 123.9 |
64.2 / 141.5 |
77.8 / 171.5 |
|||||
Electrical requirements (230V) |
60Hz, 1.3A | 50Hz, 1.3A | 60Hz, 1.4A | 50Hz, 1.4A | 60Hz, 1.5A | 50Hz, 1.5A | ||
Cat. No. | AAHB3001K | AAHB3002K | AAHB3011K | AAHB3012K | AAHB3021K | AAHB3022K | ||
Electrical requirements (120V) |
60Hz, 2.2A | 60Hz, 2.7A | 60Hz, 2.9A | |||||
Cat. No. | AAHB3003U | AAHB3013U | AAHB3023U |
General UV dose and time required
Pathogen | Average UV dose required (㎼ . s/㎠) |
Average UV time required (㎼/ ㎠ /sec.) | |||||
---|---|---|---|---|---|---|---|
PW-01 | UVC-01 | PW-11 | UVC-11 | PW-21 | UVC-21 | ||
165 | 300±10% | 185 | 350±10% | 330 | 300±20% | ||
S. enteritidis | 4,000 | 25 | 15 | 22 | 10 | 13 | 9 |
B. megatherium sp. (spores) | 2,730 | 17 | 11 | 15 | 7 | 9 | 6 |
B. subtilis | 7,100 | 43 | 27 | 39 | 18 | 22 | 16 |
Eberthella typhosa | 2,140 | 13 | 8 | 12 | 6 | 7 | 5 |
Escherichia coli (E. coli) | 3,000 | 19 | 12 | 17 | 8 | 10 | 7 |
Micrococcus candidus | 6,050 | 37 | 23 | 33 | 16 | 19 | 13 |
Proteus vulgaris | 2,640 | 16 | 10 | 15 | 7 | 8 | 6 |
Pseudomonas aeruginosa | 5,500 | 34 | 21 | 30 | 14 | 17 | 12 |
Pseudomonas aeruginosa | 3,500 | 22 | 13 | 19 | 9 | 11 | 8 |
S. typhimurium | 8,000 | 49 | 30 | 44 | 21 | 25 | 18 |
Shigella paradysenteriae | 1,680 | 101 | 7 | 10 | 4 | 6 | 4 |
Spirillum rubrum | 4,400 | 27 | 17 | 24 | 11 | 14 | 10 |
Staphylococcus albus | 1,840 | 12 | 7 | 10 | 6 | 4 |
※ Permissible environmental conditions: temperature (20 to 25℃) and relative humidity (up to 60%).
※ Above listed applications are for general purpose use.
HEPA filter (for PW)
Fluorescent lamp
UV lamp
for PCR workstations
Cat. No. | Description | PW-01 | PW-11 | PW-21 |
---|---|---|---|---|
AAAB3511 | Pre filter | - | - | |
AAAB3512 | - | - | ||
AAAB3513 | - | - | ||
EDA9219 | HEPA filter | - | - | |
EDA9220 | - | - | ||
EDA9221 | - | - | ||
CHE4436 | Fluorescent lamp | - | - | |
CHE4410 | - | - | ||
CHE4409 | - | - | ||
CHE4431 | UV lamp | - | - | |
CHE4427 | - | - | ||
CHE4423 | - | - |
Contact Us
Tel: (+86) 400 610 1188
WhatsApp/Telegram/Wechat: +86 13621645194
Follow Us: