We use cookies to help provide you with the best possible online experience. Please read our Privacy Policy for information about which cookies we use and what information we collect on our site. By continuing to use this site, you agree that we may store and access cookies on your device.
One More Step to Finalize Your Registration
An activation link has been sent to your email address.
Please check the email and activate your account now. It might take few minutes to get the email.
If you did not find it, please check your spam box.
Having problem receiving the email? Send again
Still cannot receive? Contact us
Email :PharmaSources@imsinoexpo.com
Whatsapp :+86-13621645194
Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa
Monthly Production Capacity: 1000 pieces/Month
Contract Manufacturing: CRO
Packaging Information: carton box
Delivery Lead Time: 7-10 working days
Sample Provided: no
Payment Terms: T/T, Western Union, MoneyGram
Features
1. Applicable Polarography Principle for DOG-208F Dissolved Oxygen Electrode
2. With platinum (Pt) as cathode and Ag / AgCl as anode
3. The electrolyte is 0.1 M potassium chloride (KCI).
4. The silicone rubber permeable membrane imported from U.S. serves as the permeable membrane.
5. It has silicone rubber and steel gauze.
6. It is featured by collision resistance, corrosion resistance, high. temperature resistance, shape retention and other performances
Technical Indexes
1. Measuring range: 0-20ug/L 0-20mg/L
2. Electrode shell material: 316L stainless steel
3. Temperature compensation resistor: NTC: 2.252K, Ptl00, Ptl000 and so on.
4. Sensor life: >3 years
5. Cable length: 5m (double shielded)
6. Detection lower Limit: 0.1ug/I(ppb)(20°C)
7. Measurement upper limit: 20mg/l(ppm)
8. Response time: ≤3min(90%, 20°C)
9. Polarization time: >8h
10. Minimum flow rate: 5cm/s; 515 L/h
11. Drift: <3%/month
12. Measurement error: <±1 ppb
13. Output current: 50-80nA Note: Maximum current 20-25Ua
14.Polarization voltage: 0.7V
15. Zero Oxygen: <5ppb(60min)
16. Calibration intervals: >60 days
17. Measured water temperature: 0-60 °C
Related Products
Certification
Packing & Delivery
Our Company
Customer Visitor
FAQ
Q: Are you trading company or manufacturer ?
A: We are factory.
Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. or it is 15-20 days if the goods are not in stock, it is according to quantity.
Q: Do you provide samples ? is it free or extra ?
A: We can provide the sample, it is extra
Q: What is your terms of payment ?
A: 100% T/T in advance ,balance before shippment.
If you have another question, pls feel free to contact us as below: