Safety circuit design to protect against overcurrent and overheating.
Over temperature limit function. (Over Temperature Limiter)
Error display and alarm when an abnormality occurs during operation.
If a temperature sensor error occurs during operation, the temperature control is stopped, and a warning window is displayed.
Malfunction prevented by controller lock function.
Automatic stoppage of heater and fan when door is opened.
Two series of models according to heat transfer method
Forced Convection
The structure allows for the inside air to be circulated and the temperature to be controlled, producing stable temperature control and good distribution. However, the amount of moisture evaporation of the medium is relatively high.
Save and use 3 frequently used temperatures.
The air-jacket structure heats the outside air in the space where the sample is placed and transfers the heat to the inside, and the moisture evaporation amount of the medium is relatively low.
Model
IB3-03A
IB3-05A
IB3-10A
IB3-15A
Chamber volume (L / cu ft)
30 / 1.1
50 / 1.8
100 / 3.5
120 / 4.2
Temperature
Range (℃ / ℉)
Amb. +5 to 80
/ Amb. +9 to 176
Amb. +5 to 80
/ Amb. +9 to 176
Amb. +5 to 80
/ Amb. +9 to 176
Amb. +5 to 80
/ Amb. +9 to 176
Fluctuation at 37℃ (±℃ / ℉)
0.05 / 0.09
0.1 / 0.18
0.1 / 0.18
0.15 / 0.27
Variation at 37℃ (±℃ / ℉)
0.43 / 0.77
0.25 / 0.45
0.5 / 0.9
0.52 / 0.93
Heating time to 37℃ (min.)
29
39
42
45
Recovery time at 37℃ (min.)
6
6
6
9
Dimension
(W×D×H)
Interior (W x D x H, mm / inch)
310 x 313 x 310
/ 12.2 x 12.3 x 12.2
367 x 372 x 367
14.4 x 14.6 x 14.4
463 x 467 x 463
/ 18.2 x 18.4 x 18.2
550 x 455 x 600
/ 21.7 x 17.9 x 23.6
Exterior (W x D x H, mm / inch)
488 x 649 x 503
/ 19.2 x 25.6 x 19.8
545 x 705 x 560
/21.5 x 27.8 x 22.0
641 x 802 x 655
/ 25.2 x 31.6 x 25.8
728 x 815 x 794
/28.7 x 32.1 x 31.3
Net weight (Kg / lbs)
43 / 94.8
53 / 117
63 / 139
72.5 / 160
Shelves
Quantity of shelves (standard/max.)
2 / 2
2 / 4
2 / 5
2 / 6
Max. Load per shelf (Kg / lbs)
30 / 66
30 / 66
30 / 66
30 / 66
Electrical requirements (230V, 50 / 60Hz, A)
2.3
2.8
3.5
3.8
Cat. No.
AAH21355K
AAH21365K
AAH21375K
AAH21385K
Electrical requirements (120V, 60Hz, A)
4
4.8
6.2
6.7
Cat. No.
AAH21356U
AAH21366U
AAH21376U
AAH21386U
※ The lowest temperature that can be controlled depends on changes in room temperature and sample temperature. Therefore, please contact the distributor of our products before purchasing for technical consultation.
※ Technical data (according to DIN 12880 after 2013)
Wire shelves
Excellent corrosion resistance as made of stainless steel.
Excellent air permeability and uniform temperature distribution.
Perforated shelves
Porous structure made of stainless steel.
Solid structure makes it suitable for high load samples.
LC GreenBox
Monitor and control the operation status of the device in real time via mobile app with simple internet connection.