We use cookies to help provide you with the best possible online experience. Please read our Privacy Policy for information about which cookies we use and what information we collect on our site. By continuing to use this site, you agree that we may store and access cookies on your device.
One More Step to Finalize Your Registration
An activation link has been sent to your email address.
Please check the email and activate your account now. It might take few minutes to get the email.
If you did not find it, please check your spam box.
Having problem receiving the email? Send again
Still cannot receive? Contact us
Email :PharmaSources@imsinoexpo.com
Whatsapp :+86-13621645194
Main Sales Markets: North America,Central/South America,Western Europe,Eastern Europe,Australasia,Asia,Middle East,Africa
Packaging Information: wooden case packing
Sample Provided: no
Payment Terms: Negotiable
Suppository production line output: 6500-8000 pcs / hour
Suppository production line Product Description: Suitable substrates: synthetic fatty acid glycerides / glycerinated gelatin / polyethylene glycol, etc.
Suppository production line applicable form: bullet form / Fish form/ duck mouth form and other special shapes
Equipment advantages
Detection function: 1. The PLC of run through PLC on-line monitoring function can breakdown self check alarm and show the cause of the problem simultaneously convenient operator timely troubleshooting.
2. The operation mode, the machine running in the following way: reset, automatic, manual, emptying.
2.1 reset
All parts of the machine after in the initial position, have to start the machine conditions; In manual operation or the manual way of molding machines need to be reset after operating
Ø check machine connection is correct, open the main switch
Ø manual switch in "off"
Ø press the reset button
2.2 automatically
Machine with PLC controller control the operation of the order
Ø check machine connection is correct, open the main switch
Ø install roller
Ø press the reset button
Ø press the start button
2.3 manual: on a touch screen, click on the "manual" to enter submenu, click on a single function to run
3. The thermostat setting
On the control panel is equipped with the thermostat, each a thermostat control temperature alarm peak (set) according to production needs, if exceed its value, the temperature on the display alarm lights, machine stop.