In This Store
Category:Laboratory > Other Instrument > Other Laboratory Equipment / Supplies
Product Name:The separatory funnel oscillator FY-1
Price(USD):0.00
Company:Changzhou Putian Apparatus Manufacturing Co.,Ltd
Factory Location: china jintan
Main Sales Markets: Asia
Sample Provided: no
First、technical indicators
Sample number: 6 (can also be applied to 60 ml, 250 ml 500 ml, 1000)) (2000 ml to make to order)
Speed range: start to 300r/min
Vibration amplitude: 35mm
Tilt:12mm
Vertical load: 10kg
Power source: ac220V 50Hz
Dimensions: 640 X 580 X 730mm
Second、the directions for use
2-1: medium used in the speed range, can prolong the service life of the instrument。
2-2: instrument should be placed in a strong worktable, environment should be clean and tidy, the temperature is moderate, the well ventilated。
2-3: instrument before use, first put speed control knob at the minimum position。
2-4: the clamping bottles. In the vertical table tops try bottle, lay particular stress on try bottle placed at both ends of the table should be avoided. The cultivation of the bottle
Fluid should be roughly equal, if less than several culture bottle, can place try bottle of symmetry or other equivalent load solution is full of empty seats。
2-5: through to external power, the power switch in the location of the "open", "light, slow speed rotation adjustment
Button to the required speed.
2-6: before each stop, speed control knob must be placed on the minimum position, then cut off power supply。
Third、maintenance
3-1: proper use and pay attention to the instrument maintenance, make its are in good working condition, can prolong the service life of the instrument。
3-2: instruments during the period of continuous work, once every three months should be regularly check: check whether there is water, dirt, etc into the motor and control yuan; Check the fuse, control components and tighten screw。
3-3: transmission part of the bearing has filled before they go out the right amount of grease sodium calcium (1 a), instruments during the period of continuous work, once every six months should add grease, filling quantity of bearing space I / 3。
3-4: instrument after long-term use, wear and tear is a normal phenomenon. Instruments in use after a year, if found abnormal motor noise; Transmission part bearing wear, loose belt or appear crack; Electronic component failure such as fault, the company will continue to provide quality services, assist to handle。