Structural functional features
Wide temperature range that can be controlled up to 250°C.
Improved temperature distribution (±1.5°C at 100°C)
3-point temperature calibration, high temperature accuracy over a wide temperature range.
Inner stainless steel and aluminum shelves provide excellent corrosion resistance and clean maintenance.
Protects equipment from overcurrent and over temperature through safety circuits.
Vacuum line and release line are separated and convenient to use.
The display is mounted at the top, minimizing floor size requirement.
Use Convenience Features
When a vacuum is formed and maintained, the toughened glass is attached to the gasket, so it is kept confined for long-time repeated use.
Save and use 3 frequently used temperatures.
PC connection using RS-232 port and USB port.
Excellent visibility and viewing angle due to application of 4.7-inch large VFD.
Wait On/Off timer. (up to 999 hours 59 minutes)
Toughened glass viewing window for easy internal viewing
Microprocessor PID method for precise temperature control.
Monitor via mobile app anytime, anywhere with LC Connected mobile monitoring system
(when purchased LC GreenBox)
Outstanding Safety
Door structure including buffer system allows for internal pressure release through upper and lower ventilation holes when stable vacuum is formed/maintained and when there is an internal explosion.
Polycarbonate safety cover provided in case of toughened glass breakage.
Over temperature limit function. (Over Temperature Limiter)
Safe product surface, even when operated at upper temperature.
Malfunction prevented by controller lock functio
Alarm if set temperature deviation outside of acceptable range.
Vacuum oven use configuration
It is recommended to use the cold trap bath on the vacuum line to protect the weak vacuum pump against water/solvent or to supply dry air to the sample.
Model
OV3-30
OV3-65
Chamber volume (L / cu ft)
28 / 1
65 / 2.3
Vacuum gauge range, analog (Mpa)
0 to 0.1
Temperature
Range (℃ / ℉)
Amb. +10 to 250
/ Amb. +18 to 482
Fluctuation at 100℃ (±℃ / ℉)
0.1 / 0.18
0.3 / 0.54
Variation at 100℃ (±℃ / ℉)
1.5 / 2.7
Heating time to 100℃ (min.)
110
120
Dimension(W×D×H)
Interior (W x D x H, mm / inch)
302×305×302
/ 11.9×12×11.9
402×405×402
/ 15.8×15.9×15.8
Exterior (W x D x H, mm / inch)
537 x 522 x 655
/ 21.1 x 20.6 x 25.8
636 x 622 x 755
/ 25.0 x 24.5 x 29.7
Net weight (Kg / lbs)
69 / 152.1
110 / 242.5
Shelves
Quantity of shelves (standard/max.)
2 / 2
3 / 3
Max. Load per shelf (Kg / lbs)
20 / 44.1
20 / 44.1
Electrical requirements (230V, 50 / 60 Hz, A)
5
5.8
Cat. No.
AAH13215K
AAH13225K
Electrical requirements (120V, 60 Hz, A)
10.2
11.7
Cat. No.
AAH13216U
AAH13226U
※ The lowest temperature that can be controlled depends on changes in room temperature and sample temperature. Therefore, please contact the distributor of our products before purchasing for technical consultation.
※ Technical data (according to DIN 12880, after 2013)