air disinfector purifier 916

Category:Cleanroom System > Purification Equipment
Product Name:air disinfector purifier 916
Company:Beijing Neuronbc Laboratories Co., Ltd.

Basic Info
  • Factory Location: Beijing

    Main Sales Markets: Central/South America,Eastern Europe,Asia,Africa

  • Monthly Production Capacity: 200

    Packaging Information: wooden case

  • Delivery Lead Time: 2-4周

    Sample Provided: no

    Payment Terms: T/T

    Technological parameters A916

     

    Model

    KJ1000F-A912

    Power

    A.C220V、50/60 Hz

    Rate power

    125W

    Standby power

    <1.0W

    Fuse specification

    A.C220V,2A

    Noise

    30~50dB(A)

    Anion concentration

    3*10^6/cm3

    Wind speed control

    Five level

    Word Mode

    Manual/Clock control/Sensor control

    Purification efficiency

    High level(5.2)

    Sensor unit

    PM、CO2、VO

    Weight(KG)

    41

    Dimension

    W480*D280*H1510

     

     

    Futures:

    Show the PM2.5、CO2、VOC、humidity、temperature and time automatically;

    Sensor control——Automatically adjust the working state according to the indoor PM2.5 content and VOC concentration

    Clock control——According to the user's requirements, set the automatic on / off working period for seven continuous days

    Five speed level, according to requirement setting

    3D printing adsorption device, innovative design, highly effective adsorption of inhalable particles in the air, made of non-metallic materials (PLA, PET), overcomes the shortcoming of  traditional silent adsorption device ignition (discharge climbing arc), ozone generating

    Cleaning and maintenance prompt function

    Fault prompt alarm function

    0.3µm  Primary purification rate of particulate matter                                            

    No.

    Wind speed m/s

    Primary purification rate %

    1

    1.0

    99.9

    2

    2.0

    99.8

    3

    3.0

    99.7

    4

    4.0

    99.5

    0.25µm Primary purification rate of particulate matter

    No.

    Wind speed m/s

    Primary purification rate %

    1

    1.0

    100

    2

    2.0

    100

    3

    3.0

    100

    4

    4.0

    100

     

    5 advantages enjoy every moment

     

    PM2.5、CO2、VOC、Show the PM2.5、CO2、VOC

    Show the humidity、temperature and time automatically

    Manual mode

    Clock control mode

    Sensor control mode

    Free setting, free purification

    Set on/off  8 times /day from Monday to Sunday

    One key setting, purification by yourself

    Sensor Mode

     

    Automatic detection of indoor air pollution degree, automatic operation of equipment according to pollution degree

    Control by nature and purify all the times

     

    Manual choose work mode and wind speed.

    Perfect circulation air duct, 360 〬 all-round purification

    New electrostatic adsorption device

     

    Breaking the traditional production technology of electrostatic adsorption device, using non-metallic materials to make micro power consumption adsorption device and low-voltage polarizer, and supporting the combination of driving circuit. The adsorption device not only has a significant effect on adsorbing fine particles, but also overcomes the shortcomings of ozone and arc climbing caused by metal electrostatic dust.

     

    Test conclusion:

    1. Under the condition of test temperature 20 ~ 25 ℃ and relative humidity of 40-60%, the killing rate of Staphylococcus albus is 99.98% ,after artificially sprayed in the air of 20m3 airtight room in 90 minutes, and the natural decay rate of this bacterium is 45.45%, which meets the requirements of technical code for disinfection (2002)

     

    2. Natural bacteria:

     

    Results: under the condition of ambient temperature 20-24 ℃ , relative humidity 40-56%  natural bacteria decay rate 98.78%in the air of 100 m3 in closed room after 90 minutes' .

     

    PM2.5 purification Rate:

    No.

    Detection subject

    Unit

    Time

    Pollutant concentration

    Result

     

    PM2.5 purification rate

    %

    0

    0.863mg/m3

     

    99.8

    20mins

    0.002 mg/m3

     

     

     

     

     

    臭氧浓度:Ozone concentration

    No.

    Detection subject

    Unit

    Standard

    Result

    Judge

    1

    Ozone concentration(outlet 5cm point)

    mg/m3

    <=10

    0.002

    Qualified

     

    Standby power

    W

    <=2.0

    0.8

    Qualified

     

     

     

    Application:

     

    It is suitable for hospital surgey room, delivery room, monitoring room, newborn room, burn ward, intervention, isolation ward, supply room, hemodialysis, treatment room, Stomatology, infectious ward, etc.; biological laboratory, food and drug production workshop, banking system, school, library and other environments with high requirements for air quality

     

     

     

     

     

Send your message to this supplier
  • From:
  • To:
    Beijing Neuronbc Laboratories Co., Ltd.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service