50mm Spring pretightening chromatography column tube

Category:Laboratory > Other Instrument > Other Laboratory Equipment / Supplies
Product Name:50mm Spring pretightening chromatography column tube
Price(USD):0.00
Company:CHANGZHOU RUIXI BIOTECHNOLOGY CO.,LTD.

Basic Info
  • Factory Location: changzhou

    Main Sales Markets: North America,Western Europe,Asia

  • Sample Provided: no

    50mm Spring pretightening chromatography column tube

     

    1Product Profile

    30mm Spring pre-tightening chromatographic column is automatically filled column for high pressure preparative chromatography. The advantages are as below:

     

    1can be packed in a short time without secondary dismounting which can avoid column bed bouncing.

     

    2Piston and column bed are in contact all the time so the column bed would not collapse even after a long time use which can expand service life.

     

    3can fill one more chromatographic columns only using one set  packing column machine .

    4Do not use electrical components, can be used in explosion proof area.

     

     

    2.  Have An Edge Over Competitors

     

    1)Air cylinder replaces pneumatic hydraulic. All the pipes are pneumatic pipelines, expect the chromatographic column pipe internal pressure, others are not more than 8 bar, and more security. Secondly, only using compressed air as power source,  the operating environment is more clean.

     

    2)Pipe layout is more concise .Avoid all the hydraulic components which are used to turn air pressure to hydraulic pressure, more consistency, and the space is more larger and easy to operate.

     

    3) Special design using sealing structure for the column bottom , tightening seal can be realized only buy hands.

     

    4) Our exclusive design ensures high column efficiency.

     

    5)Save reagent by short operating time.

     

     

     

     

     

     

    The brief operation introduction of SAC

    1)fix the packing column machine, and connect air pipeline .

    2)Fix the filter plate and thread on the bottom of the chromatographic column tube.

    3)Fix the chromatographic column tube into the packing column machine, then connect the two three-way ball valve.

    4)Fix the piston peek pipeline and then fix the piston connecting rod, finaly fix the disc spring.

    5)Homogenate , ultrasound.

    6)Fix screwed conduit guide sleeve , then put nut and dummy wafer into screwed conduit.

    7)Inject homogenate and wash the top of column tube.

    8)Put the piston on the top of column tube.

    9)Fall off air cylinder and press piston into the column tube.

    10)Raise air cylinder, put screwed pipe into piston rod. Connect piston peek pipeline with two three-way ball valve.

    11)Fall off screwed conduit by pressing air cylinder, press Emergency Stop Switch after liquid out of ball valve; switch ball valve and open EMS , fall off the air cylinder till finishing fix column tube.

    12)Activate the chromatographic column tube through starting pump.

    13)After the activation ,change the length of tabletting and force the nut together with tabletting .

    14)Raise the air cylinder , dismantle chromatographic column .

    15)Text chromatographic column .

     

    50mm spring column product details

     

     

     

    Column tube

    Inner diameter

    50mm

    length

    650mm

    The inner wall of processing

    Honing,polishing

    The inner wall surface roughness

    Ra≤0.4um

     

    The maximum bed height

    300mm

    The minimum bed height

    50mm

    Maximum pressure

    260bar

    Filter plate

    Aperture

    2um

    Material

    316L powder sintering filter plate

    High pressure seals

    Material

    PTFE

    Structure

    Spring-loaded V-ring

    Piston

    Material

    316L

    Distribution type

    Sector

    Connection

    Import/Export

    1/16 or1/8 pipeline

     

     

     

     

     

     

     

     

Send your message to this supplier
  • From:
  • To:
    CHANGZHOU RUIXI BIOTECHNOLOGY CO.,LTD.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service