Karl Fischer Moisture Titrator (Volumetric titration) MKV-710M

Product Name:Karl Fischer Moisture Titrator (Volumetric titration) MKV-710M
Price(USD):0.00
Company:KYOTO ELECTRONICS MANUFACTURING (Shanghai) Co., LTD.

Basic Info
  • Factory Location: Kyoto, Japan

    Main Sales Markets: Western Europe,Asia,Middle East

  • Sample Provided: yes

    Large color TFT-LCD with a touch panel (8.4-inch) enables easy key entry

    Up to 4 titrators , AT-710B potentiometric titrators or MKC-710B Coulometric or additional Volumetric MKV-710B Karl Fischer moisture titrators can be connected and simultaneous measurement is possible

    Can resume titration automatically after interruption

    Features

    • Titrant Information is stored in an IC chip in the burette unit (Smart burette)
    • New burette unit
    • Up to 4 simultaneous measurements (Simultaneous titrations)
    • Can be connected to AT-710B potentiometric titrators or MKC-710B Coulometric Karl Fischer moisture titrators
    • The main control unit and a titrator are separately located by wireless (Bluetooth(R))
    • Large color TFT-LCD with a touch panel (8.4-inch)
    • Two different user levels and permissions
    • Measurement results are converted to PDF and can be stored in a USB flash drive
    • When using ADP-611 , a patented scan mode automatically determines the optimal evaporation temperature. (Japanese Patent No. 4247093)
    • End point detection by compensating liquid resistance is adopted. (Japanese Patent No. 1896338)
    • Can resume titration automatically after interruption
    • Automatic solvent change unit is included

    Specifications

    Type Karl Fischer Moisture Titrator
    Model MKV-710M MKV-710S
    Product configuration

    MCU-710M+MKV-710+IDP-100+Automatic Solvent Change unit

    MCU-710S+MKV-710+IDP-100+Automatic Solvent Change unit

    Measuring method Karl Fischer Volumetric titration
    Measuring range 1) Water content : 0.1 to 500mgH2O (depends on KF reagent factor)
    2) Concentration : 10ppm to 100%H2O
    Burette precision 10mL burette +/- 0.015mL ; reproducibility +/- 0.005mL
    Endpoint detection By polarized potential level detected with a twin platinum electrode
    EP sense method Detection of potential level maintained during preset end time.
    End time range : 1 to 99s
    Titration form Normal titration / Back titration (Option additional burette required)
    Required solvent 30 to 100mL (in S-type titration vessel)
    Method 120
    Key operation Touch panel
    Displays 1) 8.4-inch color LCD 800 x 600 dots
    2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish / German / French

    3) Simultaneous 4-channel display (Can also display Automatic Potentiometric Titrator simultaneously)

    3) 1-channel display
    Calculation Concentration of water content , statistics data processing (mean , SD and RSD) and automatic averaging of blank value and factor value
    Data storage 500 samples
    GLP conformance

    Registration of operator / User group administration
    Titrant : Reminder of factor measurement date / Alarm to indicate remaining reagent / Reminder of piston replacement date / Reminder of reagent replacement date / History of factor measurement
    Check performance : Reminder of scheduled check date / Record of check results
    Management of conduction time : Display of operating time

    External I/O RS-232C port x4 : 
    for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP) , Evaporator
    USB ×1 : 
    for USB flash drive , A4 printer , Thermal printer , Keyboard , Barcode reader , Foot switch , USB HUB
    LAN ×1 : for Personal computer (PC) -
    Extensibility Measuring instrument : 
    Automatic Potentiometric Titrator (AT-710) , Karl Fischer Moisture Titrator (MKV-710/MKC-710)
    Three of these instruments can be added.
    -
    Automatic piston burette : Can control max 2 burette drives
    (Including two built-in burette drives)
    Evaporator ADP-611
    Ambient condition
    1) Temperature : 5 to 35°C
    2) Humidity : 85%RH or below (no condensation)
    Power source AC100 to 240V +/- 10% 50/60 Hz
    Power consumption
    Main unit : Approx. 30W
    Printer : Approx. 7W
    Dimensions
    Touch panel controller : 225(W) x 190(D) x 42(H) mm
    Titration unit : 141(W) x 292(D) x 367(H) mm (not incl. tubing)
    Stirrer : 107(W) x 206(D) x 322(H) mm (not incl. Solvent Change unit)
    Solvent Change Unit : 240(W) x 140(D) x 400(H) mm (not incl. tubing)
    Printer : 106(W) x 180(D) x 88(H) mm
    Weight
    Touch panel controller : Approx.1.5kg
    Titration unit : Approx.4.0kg
    Stirrer : Approx.2.0kg
    Solvent Change Unit : Aprox.0.6kg
    Printer : Aprox.0.4kg
    Conformity standard CE marking EMC : EN61326-1 LVD : EN61010-1 RE Directive
    Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01
Send your message to this supplier
  • From:
  • To:
    KYOTO ELECTRONICS MANUFACTURING (Shanghai) Co., LTD.
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service